Hawke 501/453/RAC cable glands are suitable for use with single wire armour ‘W’, wire braid ‘X’ and steel tape armour ‘Z’ elastomer and plastic insulated cables.
Hawke 501/453/RAC cable glands are dual certified Exd and Exe and suitable for installation in Zone 1, Zone 2, Zone 21, Zone 22 and in Gas Groups IIA, IIB and IIC, 3.2-91.6mm outside cable diameters.
When used in increased safety applications the Hawke cable gland can be used to terminate braided cables where the braid and the cable outer sheath enter into the electrical enclosure or junction box.
Exdb IIC Gb, Exeb IIC Gb, Extb IIIC, Db Aromoured Cables ATEX & IECEx Cable Gland.
Hawke 501/453/RAC cable gland is suitable for cable termination and installation in Zone 1 (21), Zone 2 (22) and Division 2 hazardous areas.
Flameproof AExd IIC Gb,
Increased Safety AExe IIC Gb
Dust AExtD Zone 21
Dual Certified Cable Gland For Hazardous Areas ATEX – IECEx
Hazardous Area Cable Gland Classification – Exdb IIC Gb, Exeb IIC Gb, Extb IIIC Db
Certificate No’s – Baseefa06ATEX0056X and IECEx BAS 06.0013X
Cable Gland Zone bbbbbbbb – Zone 1, Zone 2, Zone 21, Zone 22 and in Gas Groups IIA, IIB and IIC
Construction and Test Standards – IEC/EN 60079-0, IEC/EN 60079-1, IEC/EN 60079-7 and IEC/EN 60079-31
Ingress Protection – IP66, IP67 and IP 68 (30 metres for 7 days) to IEC/EN 60529 and NEMA 4X
Deluge Protection – DTS01
Operating Temperature Range -60°C to +100°C
Hawke Size Ref. | Entry Thread Size | Thread Length ‘H’ | Cable Acceptance Details | ‘G’ Compressed Length | Hexagon Dimensions | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Inner Sheath ‘A’ | Outer Sheath ‘B’ | ‘C’ Armour/Braid | |||||||||||||
Standard Seal | Alternative Seal (S) | ||||||||||||||
Metric | NPT * | ||||||||||||||
Standard | Option | Min. | Max. | Min. | Max. | Min. | Max. | Orien tation 1 | Orien tation 2 | Across Flats | Across Corners | ||||
Os | M20 ‡ | ½” | – | 15 | 3.0 | 8.0 | – | – | 5.5 | 12.0 | 0.8 / 1.25 | 0 / 0.8 | 52.0 | 24.0 | 26.5 |
O | M20 ‡ | ½” | – | 15 | 6.5 | 11.9 | – | – | 9.5 | 16.0 | 0.8 / 1.25 | 0 / 0.8 | 52.0 | 24.0 | 26.5 |
A | M20 | ¾” | ½” | 15 | 10.0 | 14.3 | 9.0 | 13.4 | 12.5 | 20.5 | 0.8 / 1.25 | 0 / 0.8 | 53.0 | 30.0 | 32.5 |
B | M25 | 1″ | ¾” | 15 | 13.0 | 20.2 | 9.5 | 15.4 | 16.9 | 26.0 | 1.25 / 1.6 | 0 / 0.7 | 59.5 | 36.0 | 39.5 |
C | M32 | 1¼” | 1″ | 15 | 19.5 | 26.5 | 15.5 | 21.2 | 22.0 | 33.0 | 1.6 / 2.0 | 0 / 0.7 | 64.0 | 46.0 | 50.5 |
C2 | M40 | 1½” | 1¼” | 15 | 25.0 | 32.5 | 22.0 | 28.0 | 28.0 | 41.0 | 1.6 / 2.0 | 0 / 0.7 | 68.3 | 55.0 | 60.6 |
D | M50 | 2″ | 1½” | 15 | 31.5 | 44.4/42.3 † | 27.5 | 34.8 | 36.0 | 52.6 | 1.8 / 2.5 | 0 / 1.0 | 79.0 | 65.0 | 70.8 |
E | M63 | 2½” | 2″ | 15 | 42.5 | 56.3/54.3 † | 39.0 | 46.5 | 46.0 | 65.3 | 1.8 / 2.5 | 0 / 1.0 | 78.4 | 80.0 | 88.0 |
F | M75 | 3″ | 2½” | 15 | 54.5 | 68.2/65.3 † | 49.5 | 58.3 | 57.0 | 78.0 | 1.8 / 2.5 | 0 / 1.0 | 83.7 | 95.0 | 104.0 |
G | M80 | 3½” | – | 20 | 67.0 | 73.0 | – | – | 75.0 | 89.5 | 2.0 / 3.5 | 0 / 1.0 | 95.6 | 106.4 | 115.0 |
H | M90 | 3½” | – | 20 | 67.0 | 77.6 | – | – | 75.0 | 89.5 | 2.0 / 3.5 | 0 / 1.0 | 95.6 | 115.0 | 130.0 |
J | M100 | 4″ | – | 20 | 77.0 | 91.6 | – | – | 88.0 | 104.5 | 2.5 / 4.0 | 0 / 1.0 | 95.6 | 127.0 | 142.0 |
All dimensions in millimetres (except*).
Os – F size metric entry threads are 1.5mm pitch as standard. For G size Cable Glands and above, a 2mm pitch is supplied as standard (1.5mm pitch with 15mm length of thread can be supplied) please specify when ordering.
† Smaller value is applicable when selecting reduced NPT entry option.
Sizes Os and O are available with an M16 thread size. For O size with an M16 thread, the maximum cable inner sheath diameter is 10.9mm.
Hawke 501/453/RAC cable glands are manufactured in Brass (standard), Nickel Plated Brass, 316 Stainless Steel or Aluminium. Brass NPT entries are nickel plated as standard.
Strip Cable to suit equipment as shown above and expose the armour/braid ‘I’.
‘I’ = 20mm for cable gland sizes Os to C ‘I’ = 25mm for cable gland sizes C2 to F ‘II’ = to suit equipment. If required, fit shroud.
Push the cable through the armour spigot (4). Spread armour/braid over the armour spigot (4) until the end of the armour/braid is up against the shoulder of the armour cone. bbbbbbbb the armour clamping ring (3).
Remove the inner seal (5) from the entry (6). Place the entry (6) over the armour spigot (4). Move the sub-assembly (1) and (2) up to meet the entry (6). Note: If the equipment has a threaded entry, it may be advisable to screw the entry component into the equipment to prevent twisting of the cable after step D
Hawke Cable Glands to view the complete range of hazardous area glands certified according to ATEX & IECEx for Zone 1 / Zone 2.
Flameproof Exdb and Increased Safety Exeb (Dust Extb) Dual Certified glands from Hawke include – for further information review the product pages or contact us to discuss your cable gland requirements.
501/421 Cable Gland Unarmoured – outer cable sheath cable sealing
501/423 Cable Gland Unarmoured – flameproof seal to inner/outer cable sheath with IP seal on the outer sheath
501/453 Universal Cable Gland Wire Armoured Baided Steel Tape Armoured – indoor/outdoor hazardous areas
ICG 623 Barrier Gland Unarmoured – Zone 1, Zone 2, Zone 21, Zone 22 and in Gas Groups IIA, IIB and IIC hazardous areas
ICG 653 Barrier Gland Armoured – Zone 1, Zone 2, Zone 21, Zone 22 and in Gas Groups IIA, IIB and IIC hazardous areas
Hawke防爆格兰(Hawke Cable Glands-上海颐品自动化)
Hazardous Area Cable Glands-ATEX IECEX,Exe,Exd Group II
Hawke防爆格兰代理商:上海颐品自动化科技有限公司(4008552521)
关键词:Hawke防爆格兰,Hawke防爆变径,Hawke防爆堵头,Hawke防爆呼吸阀,Hawke防爆接线盒,Hawke防爆控制箱
Hawke防爆格兰等产品规格书及相关资料-请咨询上海颐品自动化科技有限公司