你好,欢迎来到世铝网 [请登录] [免费注册]
世铝网 铝业设备
您当前的位置: 世铝网 铝业设备 其它 RCS-9625B南瑞微机保护 普通会员

RCS-9625B南瑞微机保护

加入收藏 举报
详细信息
RCS-9625B

福建省二电新能源科技有限公司

液晶插件RCS-931A    液晶面板插件RCS-931AM    液晶面板插件RCS-931AL

电源插件RCS-931A    电源插件RCS-931AM    电源插件RCS-931AL

CPU插件RCS-931A    CPU插件RCS-931AM    CPU插件RCS-931AL

交流插件RCS-931A    交流插件RCS-931AM    交流插件RCS-931AL

COM插件RCS-931A    COM插件RCS-931AM   COM插件RCS-931AL


液晶插件RCS-941A    液晶面板插件RCS-941B    液晶面板插件RCS-941D

电源插件RCS-941A    电源插件RCS-941B    电源插件RCS-941D

CPU插件RCS-941A    CPU插件RCS-941B    CPU插件RCS-941D

交流插件RCS-941A    交流插件RCS-941B   交流插件RCS-941D

COM插件RCS-941A    COM插件RCS-941B   COM插件RCS-941D


液晶插件RCS-951A    液晶面板插件RCS-951B    液晶面板插件RCS-951D    

电源插件RCS-951A    电源插件RCS-951B    电源插件RCS-951D    

CPU插件RCS-951A    CPU插件RCS-951B    CPU插件RCS-951D    

交流插件RCS-951A    交流插件RCS-951B    交流插件RCS-951D    

COM插件RCS-951A    COM插件RCS-951B    COM插件RCS-951D    


液晶插件RCS-974A    液晶面板插件RCS-974AG    液晶面板插件RCS-974FG    

电源插件RCS-974A    电源插件RCS-974AG    电源插件RCS-974FG    

CPU插件RCS-974A    CPU插件RCS-974AG    CPU插件RCS-974FG    

交流插件RCS-974A    交流插件RCS-974AG    交流插件RCS-974FG    

COM插件RCS-974A    COM插件RCS-974AG    COM插件RCS-974FG    


液晶面板插件RCS-931B    液晶面板插件RCS-931BM    液晶面板插件RCS-931BML

电源插件RCS-931B    电源插件RCS-931BM    电源插件RCS-931BML

CPU插件RCS-931B    CPU插件RCS-931BM    CPU插件RCS-931BML

交流插件RCS-931B    交流插件RCS-931BM    交流插件RCS-931BML

COM插件RCS-931B    COM插件RCS-931BM   COM插件RCS-931BML


液晶面板插件RCS-931D    液晶面板插件RCS-931DM    液晶面板插件RCS-931DML

电源插件RCS-931D    电源插件RCS-931DM    电源插件RCS-931DML

CPU插件RCS-931D    CPU插件RCS-931DM    CPU插件RCS-931DML

交流插件RCS-931D    交流插件RCS-931DM    交流插件RCS-931DML

COM插件RCS-931D    COM插件RCS-931DM   COM插件RCS-931DML


液晶插件RCS-901AL    液晶面板插件RCS-901B    液晶面板插件RCS-901D

电源插件RCS-901AL    电源插件RCS-901B    电源插件RCS-901D

CPU插件RCS-901AL    CPU插件RCS-901B   CPU插件RCS-901D

交流插件RCS-901AL    交流插件RCS-901B    交流插件RCS-901D

COM插件RCS-901AL    COM插件RCS-901B   COM插件RCS-901D

南瑞RCS-9798B、RCS-9794B通讯管理机

测控功能:

(1)10路遥信开入采集,装置遥信变位以及事故遥信;

(2)变压器高压侧断路器正常遥控分、合;

(3)IA、IC、I0、UAB、UBC、UCA、UA、UB、UC、U0、P、Q、COSф、F等14个模拟量的遥测;

(4)开关事故分合次数统计及事件SOE等;

(5)可选配2路4~20mA模拟量输出,替代变送器作为DCS电流、有功功率测量接口

南瑞RCS-9798B、RCS-9794B通讯管理机

通讯功能:

(1)2个100Mbps太网口,屏蔽超五类双绞线或光纤连接;

(2)2个RS-485串口,1个RS-232串口,其中RS-232串口用作打印口;

(3)电力行业标准DL/T667-1999(IEC60870-5-103标准)的通讯规约;

(4)Modbus通讯规约。

对时功能:

(1)软件报文对时;

(2)硬件脉冲对时功能(GPS差分电平对时或IRIG-B码对时)。

保护信息方面的主要功能:

(1)装置描述的远方查看;

(2)装置参数的远方查看;

(3)保护定值、区号的远方查看、修改功能;

(4)保护功能软压板状态的远方查看、投退;

(5)装置保护开入状态的远方查看;

(6)装置运行状态(包括保护动作元件的状态和装置的自检信息)的远方查看;

(7)远方对装置实现信号复归;

(8)故障录波(包括波形数据上送)功能。

南瑞RCS-9798B、RCS-9794B通讯管理机

1模拟量输入

外部电流及电压输入经隔离互感器隔离变换后由低通滤波器输入至模数变换器,CPU经采样数字处理后,构成各种保护继电器,并计算各种遥测量。

Ia、Ib、Ic为过流保护用模拟量输入,建议采用三相三元件方式,IA、IC为测量用CT输入。

Ios为高压侧零序电流输入,在用于小电阻接地系统中时,零序电流输入构成零序保护的Ⅰ段、Ⅱ段(Ⅱ段可整定为报警),零序电流的接入建议用套管零序电流互感器接入,若无套管零序电流互感器,在保证零序电流能满足小电流接地系统保护选择性要求前提下用三相电流之和即CT的中性线电流。

IoL为低压侧零序电流输入,可取自所用变低压侧CT中性线电流或套管零序CT电流以构成低压侧零序保护的Ⅰ段、Ⅱ段。

Ua、Ub、Uc输入在本装置中与IA、IC一起计算形成本变压器的P、Q、COSф、Kwh、Kvarh。在UA、UB、UC不接入本装置时,请将PT断线检测控制字退出。

    对厂用变低压侧测量由其他测控装置完成。

南瑞RCS-9798B、RCS-9794B通讯管理机



液晶插件RCS-902AL    液晶面板插件RCS-902BFM    液晶面板插件RCS-902DK

电源插件RCS-902AL    电源插件RCS-902BFM    电源插件RCS-902DK

CPU插件RCS-902AL    CPU插件RCS-902BFM   CPU插件RCS-902DK

交流插件RCS-902AL    交流插件RCS-902BFM    交流插件RCS-902DK

COM插件RCS-902AL    COM插件RCS-902BFM   COM插件RCS-902DK

液晶插件RCS-990A    液晶面板插件RCS-992A    液晶面板插件MUX-22A   

电源插件RCS-990A    电源插件RCS-992A    电源插件MUX-22A      

CPU插件RCS-990A    CPU插件RCS-992A    CPU插件MUX-22A      

交流插件RCS-990A    交流插件RCS-992A    交流插件MUX-22A     

COM插件RCS-990A    COM插件RCS-992A    COM插件MUX-22A      


液晶插件RCS-993A    液晶面板插件RCS-993B    液晶面板插件MUX-22A   

电源插件RCS-993A    电源插件RCS-993B    电源插件MUX-22A      

CPU插件RCS-993A    CPU插件RCS-993B    CPU插件MUX-22A      

交流插件RCS-993A    交流插件RCS-993B    交流插件MUX-22A     

COM插件RCS-993A    COM插件RCS-993B    COM插件MUX-22A      


液晶插件FOX-41A    液晶面板插件FOX-41B    液晶面板插件RCS-917A  

电源插件FOX-41A     电源插件FOX-41B    电源插件RCS-917A      

CPU插件FOX-41A    CPU插件FOX-41B    CPU插件RCS-917A       

交流插件FOX-41A    交流插件FOX-41B    交流插件RCS-917A      

COM插件FOX-41A    COM插件FOX-41B    COM插件RCS-917A     


液晶插件RCS-978E    液晶面板插件RCS-978ED    液晶面板插件RCS-978EN    

电源插件RCS-978E    电源插件RCS-978ED    电源插件RCS-978EN    

CPU插件RCS-978E    CPU插件RCS-978ED    CPU插件RCS-978EN    

交流插件RCS-978E    交流插件RCS-978ED    交流插件RCS-978EN    

COM插件RCS-978E    COM插件RCS-978ED    COM插件RCS-978EN 

液晶插件RCS-921A    液晶面板插件RCS-921C    液晶面板插件RCS-931AL

电源插件RCS-921A    电源插件RCS-921C    电源插件RCS-931AL

CPU插件RCS-921A    CPU插件RCS-921C    CPU插件RCS-931AL

交流插件RCS-921A    交流插件RCS-921C    交流插件RCS-931AL

COM插件RCS-921A    COM插件RCS-921C   COM插件RCS-931AL


液晶插件RCS-922A    液晶面板插件RCS-922B    液晶面板插件RCS-924A

电源插件RCS-922A    电源插件RCS-922B    电源插件RCS-924A

CPU插件RCS-922A    CPU插件RCS-922B    CPU插件RCS-924A

交流插件RCS-922A    交流插件RCS-922B   交流插件RCS-924A

COM插件RCS-922A    COM插件RCS-922B   COM插件RCS-924A

  品牌:南瑞继保


  · 型号:PCS-9621D


  · 加工定制:是


  · 额定电压:220V


  · 适用范围:110KV以下


  · 产品认证:-2000


  · 外形尺寸:200*188*122mm


  · 输入电压:220V


  · 额定电流:5A


  · 频率:50HZ


  · 外壳材质:金属


  · 重量:4kg


  南瑞继保PCS-9621D 站用变保护测控装置


  PCS-9621D 是适用于110kV 以下电压等级的非直接接地系统或小电阻接地系统中站用变或接地


  变的保护测控装置,可组屏安装,也可在开关柜就地安装。


  保护配置:


  l 三段复合电压闭锁过流保护


  l 高压侧正序反时限保护


  l 两段定时限负序过流保护


  l 高压侧接地保护(三段定时限零序过流保护、零序过压保护、支持网络小电流接地选线)


  l 低压侧接地保护(低压侧零序过流保护,零序反时限保护)


  l 低电压保护


  l 非电量保护(非电量保护:重瓦斯跳闸、轻瓦斯报警、超温跳闸或报警、一路备用非电量


  跳闸、一路备用非电量跳闸或报警)


  l 独立的操作回路及故障录波


  l 出口组态功能


  运行告警:


  l 事故总信号


  l CT 断线报警


  l 母线PT 断线报警


  l 控制回路断线报警


  l TWJ 异常报警


  l 过负荷报警


  l 零序Ⅲ段报警


  l 接地报警


  l 超温报警


  l 弹簧未储能报警


  l 频率异常报警


  l 轻瓦斯报警


  l 非电量2 报警


  测控功能:


  l 12 路自定义遥信开入


  l 一组断路器遥控分/合(选配方



液晶插件RCS-923A    液晶面板插件RCS-923B    液晶面板插件RCS-925A

电源插件RCS-923A    电源插件RCS-923B    电源插件RCS-925A

CPU插件RCS-923A    CPU插件RCS-923B    CPU插件RCS-925A

交流插件RCS-923A    交流插件RCS-923B   交流插件RCS-925A

COM插件RCS-923A    COM插件RCS-923B   COM插件RCS-925A


产品简介: RCS-9618CS用作110kV及以下电压等级的线变组(双圈)保护及测控装置。可组屏安装,也可在开关柜就地安装。

RCS-9618CS用作110kV及以下电压等级的线变组(双圈)保护及测控装置。可组屏安装,也可在开关柜就地安装。


保护配置:

1) 光纤分相电流差动保护(差动速断和比率差动)。

2) 四段过流保护(Ⅰ、Ⅱ、Ⅲ段可经复压和方向闭锁)。

3) 一段独立的过流反时限保护。

4) 三段零序过流保护(Ⅰ、Ⅱ段可经方向闭锁,零序电流可外加也可自产)。

5) 一段独立的零流反时限保护。

6) 加速保护 (过流加速和零序加速,零序电流可外加也可自产)。

7) 过负荷功能(报警或者跳闸)。

8) 5路非电量保护(报警或者跳闸)。

9) 零序过压保护(零序电压外接)。

10)9路可组态的独立出口。

11)独立的操作回路。


测控功能:

1)12路自定义遥信开入。

2)三组遥控分/合(至多)。

3)Iam、Ibm、Icm、I0、Ua、Ub、Uc、Uab、Ubc、Uca、U0、F、P、Q、COSф共15个遥测量。

4)事件SOE记录等。


远动通讯装置 RCS-9698G-220V,电源DC:220V 台 1 

GPS同步时钟装置 RCS-9785C,电源DC:220V 台 1 

通讯装置 RCS-9794A-220V,电源DC:220V 台 1 

ETHERNET PCS-9882AD-S,电源DC:220V 台 1 

逆变电源 GES-2K220XP,容量2000VA/1600W 台 1 

线路保护测控装置 RCS-9611CS,DC220V/5A 台 1 

站用变保护测控装置 RCS-9621CS,DC220V/5A 台 1 

电机保护测控装置 RCS-9641CS,DC220V/5A 台 1 

电容器保护测控装置 RCS-9631CS,DC220V/5A 台 1 

充电保护测控装置 RCS-9616CS,DC220V/5A 台 1 

电压并列与监视装置 RCS-9663D-II-220V-03332 台 1 



联系方式
  • 联系人: 林继尧 先生
  • 职位: 销售部
  • 真: 0139-50401334
  • 电话: 0139-50401334
  • 手机: 13950401334
  • 址: 福建省 福州市 金山桔园洲台江园37号302
供应商其他供应信息
还没找到合适的产品?