一、DRL-III 导热系数测试仪产品简介
    导热系数测定仪DRL-III型主要测试薄的热导体、固体电绝缘材料、导热硅脂、树脂、橡胶、氧化铍瓷、氧化铝瓷等材料的热阻以及固体界面处的接触热阻和材料的导热系数。检测材料为固态片状,加围框可检测粉状态材料及膏状材料。
参考标准:MIL-I-49456A(绝缘片材、导热树脂、热导玻纤增强);GB 5598-85(氧化铍瓷导热系数测定方法);ASTM D5470-2006(薄的热导性固体电绝缘材料传热性能的测试标准)等。
仪器特点:带自动加压,自动测厚装置,并连计算机实现全自动控制。仪器采用6点温度梯度检测,提高了测试精度。可检测不同压力下热阻曲线,采用优化的数学模型,可测量材料导热系数和热阻以及界面处接触热阻等多个参数。
广泛应用在高等院校,科研单位,质检部门和生产厂的材料导热分析检测。
二、DRL-III导热系数测试仪 技术指标
    ★试样大小:≤Φ30mm
    ★试样厚度:0.02-20mm
    ★热极控温范围:室温-99.99℃   
    ★冷极控温范围:0-99.0℃
    ★导热系数测试范围:0.05~45 W/m*k
    ★热阻测试范围:0.05~0.000005m2*K/W
    ★压力测量范围:0~1000N
    ★位移测量范围:0~30.00mm
    ★测试精度:优于3%
    ★实验方式:a、试样不同压力下热阻测试。b、材料导热系数测试。c、接触热阻测试。
    ★计算机全自动测试,并实现数据打印输出。


A, DRL-III thermal conductivity coefficient instrument product brief
Thermal conductivity coefficient tester type DRL-III mainly for testing thin thermal conductor, solid electrical insulating materials, thermal conductivity Guizhi, resin, rubber, beryllium oxide ceramic, alumina ceramic materials such as the thermal resistance and the solid interface contact resistance and thermal conductivity of materials. Testing of materials for solid sheet, and frame can be detected in powder material and pasty materials.
Reference standard: MIL-I-49456A ( insulating sheet, thermal conductivity, thermal conductivity of glass fiber reinforced resin ); GB 5598-85 ( BeO ceramic thermal conductivity method for determination of ASTM D5470-2006 ( thin ); the thermal conductivity of solid electrical insulating materials heat transfer performance testing standards ).
Features: with automatic pressure, automatic thickness measuring device, and even computer to realize automatic control. Apparatus employing 6 point temperature gradient detection, improves the test accuracy. Can be detected under different pressure resistance curve, the optimized mathematical model, capable of measuring thermal conductivity of materials and the thermal resistance and heat resistance at the interface of multiple parameters.
Widely used in Colleges and universities, scientific research units, quality inspection department and production plant material heat conduction analysis.
In two, DRL-III thermal conductivity coefficient instrument technology index
★sample size:≤Φ 30mm
★specimen thickness: 0.02-20mm
★heat range of temperature: room temperature -99.99 ℃
★freezing temperature range: 0-99.0 ℃
★thermal conductivity measurement range: 0.05 ~ 45 W/m*k
★thermal resistance test range: 0.05~ 0.000005m2*K/W
Of pressure measurement range: 0~ 1000N
★displacement measurement range: 0 ~ 30.00mm
★test accuracy: better than 3%
★experiment: A, sample under different pressure resistance test. B, thermal conductivity test. C, thermal contact resistance test.
★computer automatic testing, and realizes the data printout.